1.25G Cisco Sfp Transceiver Module 20KM
Pengenalan Cisco SFP Module
Rating Maksimal mutlak
| Parameter | Simbol | Min | Maksimal | Satuan |
| Tegangan Pasokan | Vcc | - 0.5 | 4.5 | V |
| Suhu penyimpanan | T | - 40 | +85 | °C |
| Kelembaban Operasi | - | 5 | 85 | % |
Kondisi operasi yang direkomendasikan
| Parameter | Simbol | Min | Tipikal | Maksimal | Satuan | |
| Suhu ruang operasi | Standar | Tc | 0 | +70 | °C | |
| diperpanjang | - 20 | +80 | °C | |||
| Industri | - 40 | +85 | °C | |||
| Tegangan Pasokan Daya | Vcc | 3.135 | 3.30 | 3.465 | V | |
| Arus Pasokan Listrik | Icc | 300 | mA | |||
| Tingkat Data | 0.1 | 1.25 | Gbit/s | |||
Karakteristik optik dan listrik
| Parameter | Simbol | Min | Tipikal | Maksimal | Satuan | Catatan | ||
| Transmitter | ||||||||
| Panjang Gelombang Pusat | λc | 1260 | 1310 | 1360 | nm | |||
| Lebar Spektral (RMS) | Δλ | 3 | nm | |||||
| Rasio penekanan mode samping | SMSR | - | - | - | dB | |||
| Daya output rata-rata | Puut | -9 | 0 | dBm | 1 | |||
| Rasio Kepunahan | Urgensi | 9.0 | dB | |||||
| Data Input Swing Differential | Nomor kendaraan | 180 | 1200 | mV | 2 | |||
| Impedansi Diferensial Masuk | ZIN | 90 | 100 | 110 | Oh | |||
| TX Matikan | Menonaktifkan | 2.0 | Vcc | V | ||||
| Aktifkan | 0 | 0.8 | V | |||||
| Kesalahan TX | Kesalahan | 2.0 | Vcc | V | ||||
| Normal | 0 | 0.8 | V | |||||
| Penerima | ||||||||
| Panjang Gelombang Pusat | λc | 1530 | 1550 | 1570 | nm | |||
| Sensitivitas penerima | - 23 tahun. | dBm | 3 | |||||
| Pengirim Terlalu Terisi | -1 | dBm | 3 | |||||
| Keterlambatan Pendaftaran | KEKUATAN | - 24 | dBm | |||||
| Pernyataan LOS | LOSA | - 38 | dBm | |||||
| LOS Hysteresis | 0.5 | 4 | dB | |||||
| Data Output Swing Differential | Vout | 600 | 800 | 1000 | mV | 4 | ||
| Los | Tinggi | 2.0 | Vcc | V | ||||
| Rendah | 0.8 | V | ||||||
Informasi pemesanan
| Nomor Bagian | Deskripsi Produk |
| OSBL1G20D-35 | 1310T/1550R, 1,25Gbps, LC, 20km, 0°C~+70°C, dengan DDM |
| OSBL1G20DI-35 | 1310T/1550R, 1,25Gbps, LC, 20km, -40°C~+75°C, dengan DDM |
![]()